457mm wide on at least three sides of every elevator machine.
Elevator machine room lighting requirements.
Access must be separate from access to the elevator cars and hoistways also known as elevator shafts.
1 there shall be a clear work space and passageway at least 18 in.
Elevator machine control room venting has appropriate fire dampers in penetrations depending on the location smoke dampers are installed in machine control room venting if floor is one or more stories above or below the level of exit discharge a two way communication system is provided at the landing serving each elevator or bank of elevators.
G work space required in machine rooms and machinery spaces.
Provide a fused disconnect switch for each elevator in the control room located in a position based on local code and within sight of elevator equipment and arranged to be locked in the off position.
The state may require permanent lighting and a minimum number of electrical outlets as well as telephone jacks for emergency phones.
Provide 110 vac service for elevator light and accessories connected to the car light service terminal on the elevator controller.
Equipment in machine rooms spaces.
You ll be responsible for specifying the items related to the fire alarm and some controls as well as supplying lighting and power to the equipment room and elevator pit.
Electrical wiring pipes and ducts in hoistways and machine rooms.
The room must be kept clean and clear of any obstructions.